Issue 107049

Summary: Slide pane jumps when selecting slide in the end of presentation
Product: Draw Reporter: wolframgarten
Component: uiAssignee: wolframgarten
Status: CLOSED FIXED QA Contact: issues@graphics <issues>
Severity: Trivial    
Priority: P3 CC: issues, rainerbielefeld_ooo_qa
Version: OOO320m5Keywords: oooqa
Target Milestone: OOo 3.2   
Hardware: Sun   
OS: All   
Issue Type: DEFECT Latest Confirmation in: ---
Developer Difficulty: ---
Issue Depends on:    
Issue Blocks: 99999    
Attachments:
Description Flags
bugdoc none

Description wolframgarten 2009-11-19 15:05:36 UTC
Open the posted bugdoc.
Use the scrollbar of the slide pane to scroll to the end.
click onto slide 16 to select it: the slide pane jumps up to the start and
selects the slide that is now in the position slide 16 was in. Ok in 3.1.1.
This does not happen if you first select the 1st slide before scrolling.
Comment 1 wolframgarten 2009-11-19 15:06:40 UTC
Created attachment 66188 [details]
bugdoc
Comment 2 wolframgarten 2009-11-19 15:09:15 UTC
Target set.
Comment 3 groucho266 2009-11-20 12:50:35 UTC
The bug is caused by the focus manager of the slide sorter.  It moves the focus
indicator into the visible area of the slide sorter view when the slide sorter
is focused.  At this time the old current slide is focused.  Therefore the old
slide is moved back into view.

Fixed by scrolling the focused slide into the visible area only when the focus
indicator is moved from one slide to another.

SVN revision of the fix is 277578.
Comment 4 groucho266 2009-11-25 09:10:40 UTC
@wg: Please verify.
Comment 5 wolframgarten 2009-11-26 09:57:42 UTC
Verified in CWS.
Comment 6 Rainer Bielefeld 2009-12-23 07:44:11 UTC
Issue 96487 seems to eb a DUP of this one?
Comment 7 Rainer Bielefeld 2009-12-23 09:45:38 UTC
Where has the fix been integrated? I still see the problem in "Ooo 3.2.0 RC1 WIN
XP DE-multilingual version English UI activated [OOo320m8 (Build 9472)]"!
Comment 8 Rainer Bielefeld 2009-12-23 09:59:51 UTC
*** Issue 105273 has been marked as a duplicate of this issue. ***
Comment 9 Rainer Bielefeld 2009-12-23 15:49:15 UTC
Please check Issue 105273, Issue 96487! There we have the same problem, but I am
not sure whether the reasons for problems in all 3 issues are the same!
Comment 10 wolframgarten 2010-01-05 14:29:08 UTC
The original bug from this issue here (i107049) is fixed for me in OOO320_m8. I