Issue 100928 - Opening the Tools->Options->Improvement Program Tabpage on first start accidently activates Usage Tracking
Summary: Opening the Tools->Options->Improvement Program Tabpage on first start accide...
Status: CLOSED FIXED
Alias: None
Product: General
Classification: Code
Component: code (show other issues)
Version: OOO310m9
Hardware: All All
: P1 (highest) Trivial (vote)
Target Milestone: OOo 3.1
Assignee: stefan.baltzer
QA Contact: issues@framework
URL:
Keywords:
Depends on:
Blocks: 90370 95768
  Show dependency tree
 
Reported: 2009-04-07 16:43 UTC by bjoern.michaelsen
Modified: 2009-05-08 10:50 UTC (History)
2 users (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments
proposed patch (731 bytes, patch)
2009-04-07 16:48 UTC, bjoern.michaelsen
no flags Details | Diff

Note You need to log in before you can comment on or make changes to this issue.
Description bjoern.michaelsen 2009-04-07 16:43:16 UTC
Steps to Reproduce:
- Open Tools->Options on first start (before the User Feedback Program
Invitation showed up)
- Select "Improvement Program" Tabpage
- Select another Tabpage
- Exit Tools->Options with "Ok"

Expected behavior:
-> No change in User Feedback Program participation preferences.

Actual behavior:
-> Usage Tracking will be activated, the invitation will not be shown.
Comment 1 bjoern.michaelsen 2009-04-07 16:45:51 UTC
blocking 90370, accepting issue
Comment 2 bjoern.michaelsen 2009-04-07 16:48:59 UTC
Created attachment 61432 [details]
proposed patch
Comment 3 bjoern.michaelsen 2009-04-08 12:01:17 UTC
applied patch on cws dba31m rev 270635
Comment 4 bjoern.michaelsen 2009-04-08 14:00:53 UTC
Patch successfully solved the major issue: The dialog in Tools->Options now
defaults to "No".

The actual behavior after the "Steps to Reproduce" is now:
Usage Tracking will be disabled (as expected), the invitation will not be shown.

I guess we can live with the missing invitation in this very special scenario
for 3.1.
Comment 5 bjoern.michaelsen 2009-04-08 14:59:13 UTC
@sba: please verify
Comment 6 stefan.baltzer 2009-04-09 11:00:59 UTC
Looks OK:
 - The options tab page defaults to "No" now.
 - Once the option page is visited, "No" is taken as set, thus no dialog on
later office start, no program participation unless pro-actively changed in
tools-options by the user.
 - Without visiting that page, the Improvement program dialog shows up on second
start and defaults to "Yes".
 - When closing this dialog via dialog closer from system, nothing is changed
(no data tracked) and the dialog wil re-occur at the next start.
 - Removing the user directory re-sets office completely (dialog at second start
defaults to "Yes", Option page defaults to "No"...)

-> Verified in CWS dba31m
Comment 7 stefan.baltzer 2009-05-08 10:50:15 UTC
OK in OOO310_m11 (= OOo 3.1) Closed.