Issue 62046 - Chart Range chooser doesn't appears
Summary: Chart Range chooser doesn't appears
Status: CLOSED FIXED
Alias: None
Product: Calc
Classification: Application
Component: editing (show other issues)
Version: recent-trunk
Hardware: All All
: P3 Trivial (vote)
Target Milestone: ---
Assignee: oc
QA Contact: issues@sc
URL:
Keywords: regression
: 62257 (view as issue list)
Depends on:
Blocks: 61850
  Show dependency tree
 
Reported: 2006-02-14 12:48 UTC by kla
Modified: 2013-08-07 15:13 UTC (History)
1 user (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments

Note You need to log in before you can comment on or make changes to this issue.
Description kla 2006-02-14 12:48:52 UTC
Insert into a cell a number.
Don't leave the insert mode.
Press Insert Chart Button.
The Chart Range chooser doesn't appears.
Comment 1 niklas.nebel 2006-02-14 15:54:31 UTC
adding dependency
Comment 2 kla 2006-02-14 16:10:11 UTC
changed target
Comment 3 niklas.nebel 2006-02-14 16:48:57 UTC
This is a regression from m156.
Also broken: Enter a formula with a reference via keyboard (press "=",
cursor-down, enter). After that, the cursor can't be moved by keyboard.
See also issue 62045.
Comment 4 niklas.nebel 2006-02-14 19:14:43 UTC
Fixed together with issue 62045 on CWS "calcnotify".
Changed:
tabvwsh4.cxx 1.53.10.1.2.1
prevwsh.cxx 1.25.114.1.2.1
Comment 5 niklas.nebel 2006-02-15 08:46:49 UTC
reassigning to QA for verification

re-open issue and reassign to oc@openoffice.org
Comment 6 niklas.nebel 2006-02-15 08:46:59 UTC
reassign to oc@openoffice.org
Comment 7 niklas.nebel 2006-02-15 08:47:02 UTC
reset resolution to FIXED
Comment 8 oc 2006-02-16 08:04:09 UTC
verified in internal build cws_calcnotify
Comment 9 pavel 2006-02-19 07:11:47 UTC
*** Issue 62257 has been marked as a duplicate of this issue. ***
Comment 10 oc 2006-02-20 13:06:05 UTC
closed because fix available in OOo2.0.2_OOB680_m2