Issue 77406 - RPT: inserted control stay selected after changing working area
Summary: RPT: inserted control stay selected after changing working area
Status: CLOSED FIXED
Alias: None
Product: Base
Classification: Application
Component: code (show other issues)
Version: recent-trunk
Hardware: All All
: P3 Trivial (vote)
Target Milestone: OOo 2.3
Assignee: christoph.lukasiak
QA Contact: issues@dba
URL:
Keywords: new_implementation
Depends on:
Blocks:
 
Reported: 2007-05-15 16:14 UTC by christoph.lukasiak
Modified: 2007-08-22 15:51 UTC (History)
1 user (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments

Note You need to log in before you can comment on or make changes to this issue.
Description christoph.lukasiak 2007-05-15 16:14:35 UTC
0. open a new database
1. create a table with any field
2. open the report designer and bind it to the table
3. open the 'add field' (button) container
4. insert any fields (with doubleclick) in the 'detail' area
5. select the 'page header' (inserted control still selected -> wrong)
6. insert any field from the 'add field' (button) container

-> field is inserted in 'detail' area (should be inserted in the 'page header')

p.s. after changing the working area, the control selection should disappear
Comment 1 christoph.lukasiak 2007-05-15 16:15:24 UTC
set keyword 'new_implementation'
Comment 2 Frank Schönheit 2007-05-22 13:04:04 UTC
The Report Designer iTeam decided that this issue is a "should fix" for the
first release of the report designer. Targeting to 2.x, thus.
Comment 3 ocke.janssen 2007-05-25 15:25:04 UTC
Fixed in cws oj14
Comment 4 ocke.janssen 2007-06-01 10:04:00 UTC
Please check. Thanks.
Comment 5 marc.neumann 2007-06-05 09:42:10 UTC
reassign to clu
Comment 6 christoph.lukasiak 2007-06-12 16:30:03 UTC
verified in cws
Comment 7 Frank Schönheit 2007-06-13 20:07:25 UTC
targeting to 2.3, since the fix is part of a CWS aiming for this release
Comment 8 christoph.lukasiak 2007-08-22 15:51:06 UTC
verified in master